Keep servers, NAS units, networks and POS tills running through outages with UPS battery backup, surge protectors and PDUs from APC, Eaton, PowerShield, Vertiv, Belkin and Tripp Lite. Genuine Australian-stock units, fast nationwide delivery, and trade pricing for multi-rack rollouts.

Top UPS & Power Brands

How to Choose the Right UPS for Your Business

An uninterruptible power supply (UPS) is cheap insurance against the most common cause of server downtime in Australia: brief mains outages, brownouts and surges. The right UPS keeps your hardware online long enough to ride out a short cut, or to shut down gracefully during a longer one. Sizing it correctly is essential — undersize and the unit overloads; oversize and you're paying for capacity you'll never use.

1. VA sizing for servers and racks

Add up the watts of every device you want protected, then convert to VA (1W is roughly 1.4VA for typical IT loads). Aim to load a UPS to 60-80% of its rated capacity to leave headroom for inrush and ageing batteries. As a rough guide:

  • Single workstation + monitor — 650-900VA (APC Back-UPS BX950U, PowerShield Defender 800)
  • POS till + receipt printer + router — 800-1100VA line-interactive
  • Small office NAS + switch + firewall — 1000-1500VA (APC Smart-UPS 1500, Eaton 5E 1100)
  • Server cabinet (1-2 1U servers + switches) — 2200-3000VA double-conversion online (APC Smart-UPS SRT, Eaton 9PX)
  • Full server rack with multiple hosts — 5-10kVA online with extended battery modules

2. Online (double conversion) vs line-interactive

Line-interactive UPS units (APC Back-UPS Pro, Eaton 5E, PowerShield Defender) are the budget choice — they correct minor sags and surges and switch to battery during outages within 4-8ms. Suitable for desktops, POS tills, NAS, and small office racks. Double-conversion online UPS units (APC Smart-UPS Online SRT, Eaton 9PX, Vertiv Liebert GXT5) continuously rebuild the AC waveform from battery, delivering perfectly clean sine wave power with zero transfer time. Recommended for production servers, medical equipment, audio gear and anywhere mains quality is poor (regional sites, sites with solar inverters or generators).

3. Runtime calculations

A UPS gives you minutes, not hours. A typical 1500VA line-interactive at 50% load delivers 10-15 minutes of runtime — enough to ride out the typical Australian outage or trigger a graceful shutdown. To extend runtime, either step up to a higher-VA model (which uses larger batteries) or add extended battery modules (XLBM/EBM). For 30-60 minute runtimes, plan an online UPS with one or two EBMs. For multi-hour operation, use a generator with a small UPS for bridging.

4. Surge protection done properly

Every Australian business should organise surge protection at three levels: service entry (lightning arrestor at the switchboard, fitted by a sparky), distribution (UPS or rack PDU with surge filtering), and point of use (Belkin or Tripp Lite surge boards rated 2000+ joules with EMI/RFI filtering). Replace consumer power boards on the server rack with proper IEC-rated PDUs. Never daisy-chain surge boards. Surge boards age with each strike — replace them every 3-5 years or after a lightning event.

5. Rack mount vs tower form factor

Choose the form factor that matches the install site. Tower UPS (APC Smart-UPS 1500, Eaton 5E) sit on the floor or under a desk — best for single servers, NAS, POS counters and home offices. Rackmount UPS (APC Smart-UPS SRT 2200RM, Eaton 9PX 3000RT, Vertiv GXT5) bolt into 19" server racks in 1U-3U — best for proper server rooms and comms cabinets. Convertible models can be mounted either way. Match the rack depth — some online UPS units are 700mm+ deep and won't fit a shallow comms cabinet. Consider a managed network card (APC AP9641, Eaton Network-M2) so you can monitor the UPS, trigger remote shutdowns and integrate with VMware, Hyper-V and Synology.

Frequently Asked Questions

What size UPS do I need for a single server?

For a typical 1U rack server with a few network switches, a 2200-3000VA double-conversion online UPS gives 10-20 minutes of runtime — plenty to ride out short outages or trigger a graceful shutdown. APC Smart-UPS SRT 2200RMXLI and Eaton 9PX 3000RT are popular choices. Email contact@techkingdom.com.au with your equipment list and we'll size it for you.

How long do UPS batteries last?

Sealed lead-acid (SLA) batteries in most line-interactive UPS units last 3-5 years before they need replacement. Online UPS units with hot-swappable battery cartridges (APC Smart-UPS SRT, Eaton 9PX) typically last 5-7 years. The UPS will alert you via beep, LED or network when batteries fail a self-test. We stock replacement cartridges for all the brands we sell.

Do I need an online UPS or is line-interactive enough?

Line-interactive is fine for desktops, POS tills, NAS units, and most small office racks. Choose double-conversion online if you have production servers, medical or lab equipment, sensitive audio/video gear, or you're on a regional site with poor mains quality. Online also lets you safely connect a generator for extended runtime.

Can I plug a laser printer into a UPS?

No — never plug a laser printer or large heater into a UPS. The startup inrush from the fuser will trip the UPS overload. Plug printers into a surge-protected outlet instead, and reserve UPS outlets for servers, networking, NAS and PCs.

How fast is delivery on UPS units?

Free shipping over $99 nationwide. Most UPS units dispatch same business day if ordered before 2pm AEST. Larger 5-10kVA online UPS units with EBMs may ship from supplier within 2-3 days. We can stage rack rollouts to match your install schedule.

Need help sizing a UPS or rack PDU?

Send us your rack equipment list — we'll calculate the load, recommend the right UPS, EBMs, rack PDUs and surge protection, and bundle it with shutdown software. Call 1300 797 866 or email contact@techkingdom.com.au.